您好,欢迎进入厦门雄霸电子商务有限公司!

全国咨询热线

18059884797

热门关键词: ABB GE A-B TRICONEX Schneider

269PLUS-100P-120AC 电机管理继电器

269PLUS-100P-120AC是GE Multilin制造的电机管理继电器。这个继电器是100欧姆,有一个铂金RTD。箱体尺寸为11.40英寸× 7.50英寸× 16.00英寸(宽×高×深),重量为7.75磅。存储和操作的环境温度应在-25℃~ 60℃之间。

联系电话:18059884797

产品详情

269PLUS-100P-120AC 电机管理继电器

 

269-PLUS-DO-100P-125V.jpg


【功能描述】

 

269PLUS-100P-120AC是GE Multilin制造的电机管理继电器。这个继电器是100欧姆,有一个铂金RTD。箱体尺寸为11.40英寸× 7.50英寸× 16.00英寸(宽×高×深),重量为7.75磅。存储和操作的环境温度应在-25℃~ 60℃之间。


本部件的订货代码以“269 PLUS”开头,表示GE Multilin的产品系列。后面的两位数字是版本:SV =标准版本;DO =退出版本。下一位数字表示相位CT和接地CT(仅DO时需要):1 = 5,2000:1;2 = 5,5;3 = 1, 2000:1;4 = 1,5。下一位数字表示继电器故障安全码(仅DO需要):1 = FS (Trip), NFS (Alarm), NFS (Aux1), FS (Aux2);2 = NFS (Trip), FS (Alarm), NFS (Aux1), FS (Aux2);3 = FS (Trip), FS (Alarm), NFS (Aux1), FS (Aux2);4 = NFS (Trip), NFS (Alarm), FS (Aux1), FS (Aux2);5 = FS (Trip), NFS (Alarm), FS (Aux1), FS (Aux2);6 = NFS (Trip), FS (Alarm), FS (Aux1), FS (Aux2);7 = FS (Trip), FS (Alarm), FS (Aux1), FS (Aux2);8 = NFS (Trip), NFS (Alarm), NFS (Aux1), FS (Aux2)。下一位数字表示继电器触点排列(仅限DO时需要):1 = N.O.(报警),N.O.(辅助),N.O.(辅助);2 = N.O.(报警),N.O. (Aux1), N.C. (Aux2);3 = N.O.(报警),N.C. (Aux1), N.O. (Aux2);4 = N.O.(报警),N.C. (Aux1), N.C. (Aux2);5 = N.C.(报警),N.O. (Aux1), N.O. (Aux2);6 = N.C.(报警),N.O. (Aux1), N.C. (Aux2);7 = N.C.(报警),N.C. (Aux1), N.O. (Aux2);8 = N.C.(警报),N.C. (Aux1), N.C. (Aux2)。接下来的3-4位数字表示欧姆和RTD材料:100P = 100欧姆铂RTD;10C = 10欧姆铜RTD;100N = 100欧姆镍RTD;120N = 120欧姆镍RTD。后两位数字表示控制电源:HI = 80—300 VDC/65—265 VAC控制电源;LO = 20 - 60vdc /20 - 48vac控制电源。


关于269PLUS-100P-120AC的常见问题

Multilin 269PLUS-100P-120AC电机管理数字继电器指定了什么继电器触点安排?

269PLUS-100P-120AC Multilin电机管理继电器不是延长版本。如果269PLUS-100P-120AC是拉拔版本,则可以在269PLUS Multilin继电器的母部件号中找到D/O字母指示器。在这种情况下,269PLUS-100P-120AC中没有D/O指示。因此继电器触点布置是不需要的(它只需要的D/O)。D/O版本具有为告警和辅助1、辅助2指定的继电器触点安排。例如,由数字4指定的D/O继电器将分别具有N.O, N.C., N.C.的继电器报警,Aux1, Aux2安排。


269PLUS-100P-120AC 电机管理继电器

 

269-PLUS-DO-100P-125V.jpg


 

269PLUS-100P-120AC is a motor management relay that is manufactured by GE Multilin.   This relay is 100 Ohm and has a platinum RTD.   The shipping box is 11.40 inches x 7.50 inches x 16.00 inches (W x H x D). The shipping weight is 7.75 lb. The ambient temperature for storage and operation must fall between -25°C-60°C.


The ordering code for this part begins with “269 PLUS,” which indicates the series by GE Multilin.   The next two digits are the version: SV = standard version;   DO = drawout version.   The next digit indicates the phase CT and the ground CT (required for DO only): 1 = 5, 2000:1;   2 = 5, 5;   3 = 1, 2000:1;   4 = 1, 5.   The next digit indicates the relay fail safe code (required for DO only): 1 = FS (Trip), NFS (Alarm), NFS (Aux1), FS (Aux2);   2 = NFS (Trip), FS (Alarm), NFS (Aux1), FS (Aux2);   3 = FS (Trip), FS (Alarm), NFS (Aux1), FS (Aux2);   4 = NFS (Trip), NFS (Alarm), FS (Aux1), FS (Aux2);   5 = FS (Trip), NFS (Alarm), FS (Aux1), FS (Aux2);   6 = NFS (Trip), FS (Alarm), FS (Aux1), FS (Aux2);   7 = FS (Trip), FS (Alarm), FS (Aux1), FS (Aux2);   8 = NFS (Trip), NFS (Alarm), NFS (Aux1), FS (Aux2).   The next digit indicates the relay contact arrangement (required for DO only): 1 = N.O. (alarm), N.O. (Aux1), N.O. (Aux2);   2 = N.O. (alarm), N.O. (Aux1), N.C. (Aux2);   3 = N.O. (alarm), N.C. (Aux1), N.O. (Aux2);   4 = N.O. (alarm), N.C. (Aux1), N.C. (Aux2);   5 = N.C. (alarm), N.O. (Aux1), N.O. (Aux2);   6 = N.C. (alarm), N.O. (Aux1), N.C. (Aux2);   7 = N.C. (alarm), N.C. (Aux1), N.O. (Aux2);   8 = N.C. (alarm), N.C. (Aux1), N.C. (Aux2).   The next 3-4 digits indicate the Ohm and RTD material: 100P = 100 Ohm platinum RTD;   10C = 10 Ohm copper RTD;   100N = 100 Ohm nickel RTD;   120N = 120 Ohm nickel RTD.   The last two digits indicate the control power: HI = 80 – 300 VDC/65 – 265 VAC control power;   LO = 20 – 60 VDC/20 – 48 VAC control power.


Frequently Asked Questions about 269PLUS-100P-120AC

What relay contact arrangement is specified for the Multilin 269PLUS-100P-120AC motor management digital relay?

The 269PLUS-100P-120AC Multilin motor management relay is not a drawout version.   If the 269PLUS-100P-120AC was a drawout version a D/O letter indicator would be found in the parent part number for the 269 PLUS Multilin relay.   In this case there is no D/O indication in the 269PLUS-100P-120AC.   Thus the relay contact arrangement is not required (it is only required for the D/O).   D/O versions have relay contact arrangements specified for the Alarm and the Aux1 and Aux2.   For example a D/O relay specified by the number 4 would have a N.O, N.C., N.C. arrangement for the relays alarm, Aux1, Aux2 respectively.


 

269PLUS-100P-120AC 电机管理继电器

 

姗姗名片合并2(1).jpg


 

【联系我们】

 

厦门雄霸电子商务有限公司

厦门市思明区吕岭路1733号创想中心2009-2010单元

联系人:珊妮

电话:18059884797

电子邮件:2082431634 qq.com

QQ2082431634

 

【常问问题】

 

1.保修怎么样?

所有产品均享有1年保修。

2.什么是交货时间?

通常1-3个工作日

3.其他供应商的价格比您好吗?


查看更多 >>

产品推荐

18059884797