369-HI-R-B-0-0 相电流输入

控制功率范围110至250 VDC, 100至240 VAC在50/60 Hz

差动开关延时< 200ms

尺寸大约。29.6厘米高× 10.7厘米宽× 20.5厘米长

i级绝缘

相电流输入1 A和5 A二次

RTD输入3根线,100根Ω铂,100根Ω镍,120根Ω镍,10根Ω铜

体重约。10磅


联系电话:18059884797

产品详情

369-HI-R-B-0-0 相电流输入

369-HI-0-M-F-E-0.jpg


【功能描述】

369-HI-R-B-0-0技术规范

控制功率范围110至250 VDC, 100至240 VAC在50/60 Hz

差动开关延时< 200ms

尺寸大约。29.6厘米高× 10.7厘米宽× 20.5厘米长

i级绝缘

相电流输入1 A和5 A二次

RTD输入3根线,100根Ω铂,100根Ω镍,120根Ω镍,10根Ω铜

体重约。10磅

产品描述

虽然电机系统管理并非易事,但通用电气Multilin的369-HI-R-B-0-0凭借其自适应能力和先进的计量技术简化了流程。旨在保护,监控和管理中型交流电机系统,369-HI-R-B-0-0具有各种工具可供使用(如快速跳闸程序和FlexCurve™技术),以延长电机寿命并减少停机时间。


该模型还包括可选的后旋检测,这是该部件的许多其他版本中没有包含的功能。后旋检测改进,还包括更通用的计量功能,可以检测泵电机的流量反转,然后在最快的安全时间间隔内安排电机重新启动。这个过程可以很容易地纠正反向旋转,恢复电机系统的正常功能。这既可以最大限度地减少停机时间,也可以减少如果不检查问题可能发生的电机损坏。


369-HI-R-B-0-0的电机健康报告功能内置到模型的每个版本,并在停止和启动过程中提供对电机历史操作的关键见解。报告内载有下列内容:


历史时间轴显示启动、重启、停止、报警和跳闸操作


所有汽车旅行的历史记录


启动趋势数据包括电压、电流、电流不平衡、TCU (thermal capacity used)、空开触点状态


运动习得信息


可以查看所有这些数据,以便更轻松地制定适当的维护计划,减少故障排除时间并降低总体运营成本。

369-HI-R-B-0-0 相电流输入

369-HI-0-M-F-E-0.jpg

369-HI-R-B-0-0 Technical specification

Control power range 110 to 250 VDC, 100 to 240 VAC at 50/60 Hz

Differential switch delay < 200ms

The size is about. 29.6 cm high x 10.7 cm wide x 20.5 cm long

Class i insulation

Phase current input 1 A and 5 A twice

RTD Input 3 wires, 100 Ω platinum, 100 Ω nickel, 120 Ω nickel, and 10 Ω copper

Weighs about. Ten pounds

Product description

While motor system management is no easy task, GE Multilin's 369-HI-R-B-0-0 simplifies the process with its adaptive capabilities and advanced metering technology. Designed to protect, monitor and manage medium sized AC motor systems, the 369-HI-R-B-0-0 has a variety of tools at its disposal, such as a quick trip program and FlexCurve™ technology, to extend motor life and reduce downtime.


The model also includes optional backspin detection, a feature not included in many other versions of the part. Backspin detection improvements also include a more general metering function that detects the flow reversal of the pump motor and then schedules the motor restart within the fastest safe time interval. This process can easily correct the reverse rotation and restore the normal function of the motor system. This both minimizes downtime and reduces motor damage that can occur if the problem is not checked.


The motor health reporting feature of the 369-HI-R-B-0-0 is built into every version of the model and provides key insights into the motor's historical operation during stop and start. The report contained the following:


The history timeline shows start, restart, stop, alarm, and trip operations


History of all car trips


The startup trend data includes voltage, current, current imbalance, thermal capacity used (TCU), and switch contact status


Motion acquisition information


All of this data can be viewed to make it easier to develop a proper maintenance plan, reduce troubleshooting time and reduce overall operating costs.

369-HI-R-B-0-0 相电流输入

姗姗名片合并2(1).jpg

【联系我们】


厦门雄霸电子商务有限公司

厦门市思明区吕岭路1733号创想中心2009-2010单元

联系人:珊妮

电话:18059884797

电子邮件:2082431634 qq.com

QQ:2082431634



【常问问题】


1.保修怎么样?

所有产品均享有1年保修。

2.什么是交货时间?

通常1-3个工作日

3.其他供应商的价格比您好吗?

“为客户创造利益是我们的信念。如果您有更好的价格,请告诉我们。我们会尽力满足您的价格并支持您

4.发货怎么样?

我们可以安排发货以具有竞争力的价格,例如顺丰,德邦等


查看更多 >>

产品推荐

18059884797