型号:IC200ALG322
热降额:IC200ALG320, bxiaoao4200
模块IC200ALG321、IC200ALG322、bxiaoao4205和bxiaoao4210无热降额。
对于模块IC200ALG320和bxiaoao4200,最小
每个通道的推荐负载电阻取决于环境温度、外部电压以及模块和din导轨的方向。下面显示的所有模块方向具有相同的降额。总负载要求包括被驱动换能器的阻抗。在较高的环境温度下,可能需要与负载串联增加电阻以达到最小负载
要求。
电缆屏蔽连接
IC200ALG322所有模拟通道的连接建议使用屏蔽双绞线。
如果该模块安装在终端式IO载波(ic200chso01002,或005)或紧凑型终端式IO载波(ic200chso022025)上,电缆屏蔽可以根据现场接线表直接连接到载波上。辅助lO端子带(IC200TBMO01,002,或005)也可以添加到终端式IO载波中,以辅助接地屏蔽。如果您计划将其用于此目的,请务必将辅助lO端子带接地。
IC200ALG322如果该模块安装在连接器式lO载体上
(IC20OCHSO03),屏蔽电缆可以直接连接到一个
插接端子(ic200chs011,012015)。一定要接地接线板。建议在插入端子和连接器底座之间也使用屏蔽的插入电缆。定制屏蔽电缆可以使用连接器套件
(IC20OACC304)。此外,还可以在标准插接电缆(IC200CBL105,110,120,230)上缠绕定制屏蔽编织。如果使用这种方法,请确保将辫子接地。
所有电缆屏蔽连接应连接到地面,并保持尽可能短的实用。电源线不需要安装
屏蔽。
Model: IC200ALG322
Heat derating :IC200ALG320, bxiaoao4200
Modules IC200ALG321, IC200ALG322, bxiaoao4205 and bxiaoao4210 have no heat derating.
For modules IC200ALG320 and bxiaoao4200, the minimum
The recommended load resistance for each channel depends on the ambient temperature, the external voltage, and the orientation of the module and the din rail. All module directions shown below have the same derating. The total load requirements include the impedance of the transducer being driven. At higher ambient temperatures, resistance may need to be increased in series with the load to achieve minimum load
Ask.
Cable shield connection
IC200ALG322 Shielded twisted pair cables are recommended for connecting all analog channels.
If the module is installed on a terminal type IO carrier (ic200chso01002, or 005) or a compact terminal type IO carrier (ic200chso022025), the cable shield can be connected directly to the carrier according to the field wiring table. The auxiliary lO terminal strip (IC200TBMO01,002, or 005) can also be added to the terminal type IO carrier to assist in grounding shielding. If you plan to use it for this purpose, be sure to ground the auxiliary lO terminal strip.
IC200ALG322 If the module is mounted on a connector lO carrier
(IC20OCHSO03), the shielded cable can be directly connected to one
Connector terminal (ic200chs011,012015). Be sure to ground the patch panel. It is recommended to also use a shielded insertion cable between the insertion terminal and the connector base. Custom shielded cables can be made using connector kits
(IC20OACC304). In addition, custom shield braids can be wrapped around standard plug cables (IC200CBL105,110,120,230). If using this method, be sure to ground the braid.
All cable shielding connections should be connected to the ground and kept as short and practical as possible. The power cable does not need to be installed
Block.