保修:12个月保修涵盖所有新零件

测量范围:相对湿度0-100%,

温度-40C至85C

精度︰相对湿度1%(10%至90%),

温度0.2C(-10C至70C)

输出信号:4-20mA或HARTR..


联系电话:18059884797

产品详情

FOXBORO-RH916XZ PLC模块 温度传感器

FOXBORO-RH916XZ.jpg

型号:FOXBORO RH916XZ

类别: DCS系统

产品类型:PLC模块

产地:美国制造

保修:12个月保修涵盖所有新零件


FOXBORO RH916XZ温度传感器

FOXBORO RH916XZ温度传感器本文提供FOXBORO RH916XZ的产品参数、规格、应用领域、使用说明、介绍以及技术说明,同时提供常见问题解释,以帮助用户更好地了解该产品。

测量范围:相对湿度0-100%,

温度-40C至85C

精度︰相对湿度1%(10%至90%),

温度0.2C(-10C至70C)

输出信号:4-20mA或HARTR..

FOXBORO RH916XZ触电、爆炸或电弧闪光

的危险FPS240-24 (PO924SM)和FPS120-24 (P0924SL)电源的输出电压默认设置为24.1 V。此电压不得更改。请勿暴露或

转动这些电源上的输出电压电位器。这样做将使这些电源及其连接的任何设备的保修失效,并可能导致设备运行

故障。如果此输出电压发生变化,Foxboro 不保证任何200系列子系统设备的运行。不遵守这些说明将导致死亡或重伤。

来自电源的干扰PLC系统控制的正常电源

由电网供电。由于电网覆盖范围广,会受到所有空间电磁干扰。空间中的辐射电磁场(EMI))主要由电网、电气设备、雷电、无线电广播、电视.雷达等的瞬态过程产生,俗称辐射干扰。如果将PLC系统置于射频场中,它将受到辐射千扰并在线路上感应出电压。特别是电网内部的变化,如刀开关操作引起的浪涌、大型电力设备的启动和关闭、交直流输电装置引起的谐波、电网短路引起的瞬态冲击等,都是通过输电线路传递到电源的。可能会造成程序错误或算术错误,导致输入输出错误,从而导致设备失控和故障,从而不能保证PLC的正常运行。

FOXBORO-RH916XZ PLC模块 温度传感器

FOXBORO-RH916XZ.jpg

Model :FOXBORO RH916XZ

Category: DCS system

Product type :PLC module

Origin: Made in the USA

Warranty: The 12-month warranty covers all new parts


FOXBORO RH916XZ Temperature sensor

FOXBORO RH916XZ Temperature Sensor This document provides the product parameters, specifications, application areas, instructions for use, introduction, and technical description of the FOXBORO RH916XZ, as well as frequently asked questions to help users better understand the product.

Measuring range: relative humidity 0-100%,

Temperature -40C to 85C

Accuracy: Relative humidity 1%(10% to 90%),

Temperature 0.2C(-10C to 70C)

Output signal :4-20mA or HARTR...

FOXBORO RH916XZ Electric shock, explosion, or arc flash

The output voltage of the FPS240-24 (PO924SM) and FPS120-24 (P0924SL) power supplies is set to 24.1V by default. This voltage cannot be changed. Do not expose or

Turn the output voltage potentiometer on these power supplies. Doing so will void the warranty on these power supplies and any equipment connected to them and may cause the equipment to operate

Faulty. If this output voltage changes, Foxboro does not guarantee the operation of any 200 Series subsystem device. Failure to comply with these instructions will result in death or serious injury.

Interference from the power supply Normal power supply controlled by the PLC system

It is powered by the grid. Due to the wide coverage of the power grid, it will be subject to all spatial electromagnetic interference. Radiation electromagnetic fields (EMI) in space are mainly generated by power grids, electrical equipment, lightning, radio broadcasting, and television. Radar and other transient processes are generated, commonly known as radiation interference. If the PLC system is placed in the RF field, it will be affected by radiation and sense voltage on the line. In particular, changes within the power grid, such as surges caused by knife switch operation, startup and shutdown of large power equipment, harmonics caused by AC/DC transmission devices, transient shocks caused by grid short circuits, etc., are transmitted to the power supply through the transmission line. May cause program errors or arithmetic errors, resulting in input and output errors, resulting in equipment out of control and failure, which can not guarantee the normal operation of the PLC.

姗姗名片合并2(1).jpg

07AC91 531X187VCTADG18440-18315X00481G01
81EU01E-E 531X189LTBAHG1531X129SNCG16DD1683-0CC0
140CPU65260 531X189LTBAJG1531X132APGAAG16ES5948-3UR21
140CPU67160 531X189LTBAKG1531X132APGACG16ES7626-2DG04-0AE3
140CPU67160C531X190SRCAFG1531X133PR0APG11394-SJT22-A
140CPU67260 531X190SRCAFG3531X133PROAG11394-SR9A
216AB61531X190SRCAFG41785-L40B2102-1201
216NG63A531X190SRCAGG11785-L40C153009


查看更多 >>

产品推荐

18059884797