ACC-24E2A是Delta Tau公司生产的UMAC Turbo系统的一部分,是一种2轴模拟接口模块,由用于2轴控制的单个ACC-24E2A或用于4轴控制的2轴ACC-24E2A 2轴模拟伺服接口板组成。Acc-24E2A轴接口和分线板为模拟伺服接口的2个或4个通道提供接口电路和分线连接器。
OMRON / Delta Tau ACC-24E2A UMAC Turbo 4 轴模拟接口模块
该板由两块互连的 UMAC Turbo ACC-24E2A 2 轴板组成,总共具有 4 轴控制功能。
连接器配置: • 选项 1:两个附加轴(共四个)
• 选项 1A:模拟 +/- 10 VDC 命令信号
• 选件 TB:接线端子编码器连接器
部件号: 603398-104, 603398-554
接线端子夹层板
部件号:
603276-100
ACC-24E2A模拟接口模块是用于连接模拟信号的接口模块,它可以将模拟信号转换成数字信号,或者将数字信号转换成模拟信号。
ACC-24E2A模拟接口模块通常用于测量和控制各种物理量,如温度、压力、位移、速度等。在工业自动化领域,模拟接口模块被广泛应用于各种传感器和执行器的数据采集和控制。
ACC-24E2A模拟接口的优点有:
前后端分离开发,提高开发效率。
增加单元测试的真实性,提高代码质量。
开发无侵入,不需要修改既有代码,就可以拦截Ajax请求,返回模拟的响应数据。
用法简单,符合直觉的接口。
数据类型丰富,支持生成随机的文本、数字、布尔值、日期、邮箱、链接、图片、颜色等。
方便扩展,支持扩展更多数据类型,支持自定义函数和正则。
ACC-24E2A模拟接口的缺点有:
容易受到干扰和噪声的影响,导致信号失真或干扰。
通常需要更多的电缆和连接器,可能会增加成本和复杂性。
The AC-24E2A, part of the UMAC Turbo system produced by Delta Tau, is a 2-axis analog interface module consisting of a single AC-24E2A for 2-axis control or a 2-axis AC-24E2A 2-axis analog servo interface board for 4-axis control. The AC-24E2A shaft interface and split-board provide interface circuits and split-connectors for 2 or 4 channels of analog servo interfaces.
OMRON/Delta Tau AC-24E2A UMAC Turbo 4-axis analog interface module
The board consists of two interconnected UMAC Turbo AC-24E2A 2-axis boards with a total of 4-axis control functions.
Connector configuration: • Option 1: Two additional shafts (four in total)
• Option 1A: Simulate the +/ -10 VDC command signal
• Option TB: terminal encoder connector
Part number: 603398-104, 603398-554
Wiring terminal sandwich plate
Part Number:
603276-100.
The AC-24E2A analog interface module is an interface module for connecting analog signals, which can convert analog signals into digital signals, or digital signals into analog signals.
The AC-24E2A analog interface module is commonly used to measure and control various physical quantities such as temperature, pressure, displacement, velocity, etc. In the field of industrial automation, analog interface modules are widely used in data acquisition and control of various sensors and actuators.
The advantages of the ACC-24E2A analog interface are:
Separate development of front and back end, improve development efficiency.
Increase the authenticity of unit tests and improve code quality.
Development is non-intrusive, and without modifying existing code, you can intercept Ajax requests and return simulated response data.
Easy to use, intuitive interface.
Rich data types, supporting the generation of random text, numbers, Boolean values, dates, mailboxes, links, pictures, colors, and so on.
Easy to expand, support to expand more data types, support custom functions and RE.
The disadvantages of the ACC-24E2A analog interface are:
Susceptible to interference and noise, resulting in signal distortion or interference.
More cables and connectors are often required, potentially increasing cost and complexity.