您好,欢迎进入厦门雄霸电子商务有限公司!

全国咨询热线

18059884797

热门关键词: ABB GE A-B TRICONEX Schneider

KUC711AE101-3BHB004661R0101 ABB 电源监测

将操作模式开关转换从STOP位置到MRES位置并保持至少3秒钟,直到红色的"STOP”发光二极管开始慢闪为止。请释放开关,并且最多在3秒内将开关再次转到MRES位置。当"STOP"LED快闪时,CPU已经被复位。如果"STOP”发光二极管没有开始快闪,请重复执行此过程。

联系电话:18059884797

产品详情

KUC711AE101-3BHB004661R0101 ABB 电源监测

KUC711AE101-3BHB004661R0101.jpg

KUC711AE1013BHB004661R0101中央处理单元(CPU)

将操作模式开关转换从STOP位置到MRES位置并保持至少3秒钟,直到红色的"STOP”发光二极管开始慢闪为止。请释放开关,并且最多在3秒内将开关再次转到MRES位置。当"STOP"LED快闪时,CPU已经被复位。如果"STOP”发光二极管没有开始快闪,请重复执行此过程。

复位存储器的方法:将操作模式开关转换从STOP位置到MRES位置,STOP LED熄灭1s,亮1s,再熄灭1s后保持亮。放开开关,使它回到

STOP位置,3s内把开关又回到MRES,STOP LED以2Hz的频率至少闪动3s,表示正在复位,最后STOP LED一直亮,可以松动模式开关,完成。

步骤复位CPU存储器

1.将钥匙转至STOP位置。

2.将钥匙转至MRES位置并保持在此位置,直至STOP LED第二次点亮并持续处于点亮状态(需要3秒)。现在释放钥匙。

3.必须在3秒内再次将钥匙转至MRES位置并保持不动,直至STOP LED闪烁(频率为2Hz)。现在即可释放开关。CPU完成存储器复位后,STOP LED 会停止闪烁并始终亮起。CPU已完成对存储器的复位。


1.电源输出:ABBR KUC711AE1013BHB004661R0101电源模炔主要功能之一是提供稳定的电源翰出,以满足系统和设备的电力需求。

2电压调节:一些ABB KUC711AE1013BHB004661R0101电源模块О可能具有电压调节功能,以便棍据需求调整输出电压。

3.电流保护:ABB KUC711AE1013BHB004661R0101电源模炔通常具有电流保护功能,以防止过电流情况对系统和设备造成损害。

4.过载保护:一些模块可能支持过载保护,以防止过高的负载情况。

5.热保护:ABB KUC711AE1013BHB004661R0101电源模块可能具有热保护功能,以防止过热情兄。

6.故障检测:模块可能支持故障检测和报警功能,帮助识别电源问题并提供警报。

7.电源过蹰: ABB KUC711AE1013BHB004661RO101电源模块可能具有电源过滤功能,以减少电源中的干扰和噪声。

8.电源监测:一些模块可能支持电源监测功能,以监测电源的状态和性能。

9.冗余性:在一些应用中,ABB KUC711AE1013BHB004661R0101电源模块可能支持冗余配置,以确保系统的可靠性。

KUC711AE101-3BHB004661R0101 ABB 电源监测

KUC711AE101-3BHB004661R0101.jpg

KUC711AE1013BHB004661R0101 central processing unit (CPU)

Switch the operating mode switch from the STOP position to the MRES position and hold it for at least 3 seconds until the red "STOP "light-emitting diode begins to flash slowly. Release the switch and turn the switch again to the MRES position within a maximum of 3 seconds. When the "STOP"LED flashes, the CPU has been reset. If the "STOP "LED does not start flashing, repeat this process.

The method of resetting the memory is to switch the operation mode from the STOP position to the MRES position, and the STOP LED is off for 1s, on for 1s, and then on for 1s. Let go of the switch and bring it back

In the STOP position, turn the switch back to MRES within 3s, and the STOP LED flashes at a frequency of 2Hz for at least 3s, indicating that it is being reset. Finally, the STOP LED is always on, and the mode switch can be loosened.

Step Reset the CPU memory

1. Turn the key to the STOP position.

2. Turn the key to the MRES position and keep it there until the STOP LED lights up for a second time and stays on (3 seconds). Now release the key.

3. You must turn the key to the MRES position again within 3 seconds and hold it still until the STOP LED flashes (frequency is 2Hz). Now release the switch. After the CPU completes the memory reset, the STOP LED will stop flashing and always light up. The CPU has reset the memory. Procedure



1. The power supply output: ABBR KUC711AE1013BHB004661R0101 power supply module and acetylene one of the main function is to provide the power of the stable hands out, in order to satisfy the demands of system and equipment of electric power.

ABB О KUC711AE1013BHB004661R0101 power supply module 2 voltage regulation: some may have a voltage regulating function, so that the rod according to the demand to adjust output voltage.

3. Current protection: ABB KUC711AE1013BHB004661R0101 power supply module and acetylene usually has a current protection function, in order to prevent the over current situation on the system and equipment damage.

4. Overload protection: Some modules may support overload protection to prevent excessive load situations.

5. Thermal protection: ABB KUC711AE1013BHB004661R0101 power supply module may have thermal protection function, to prevent a passion brother.

6. Fault detection: The module may support fault detection and alarm functions to help identify power problems and provide alerts.

7. The power lead Chu: ABB KUC711AE1013BHB004661RO101 power supply module may have a power supply filter function, in order to reduce the interference and noise of the power supply.

8. Power monitoring: Some modules may support power monitoring functions to monitor the status and performance of the power supply.

9. Redundancy: in some applications, ABB KUC711AE1013BHB004661R0101 power module may support redundant configuration, to ensure the reliability of the system.

姗姗名片合并2(1).jpg

其他相关产品型号
HID2030SKABBMB510 3BSE002540R1
3500/42MABBDAPI100 3AST000929R109
AI04ABBCI522A 3BSE018283R1
GOP2SCANLAB INTELLISCANDE III14-532NM SCANLAB
FBMSVHBENTLY3500/22M 138607-02
CLSR-33-N2CE-1ABBUFC762AE101 3BHE006412R0101
PCD3.E165ABBXVC767AE105 3BHB007209R0105
PCD3.W610ABBXVC768115 3BHB007211R115
PCD3.W340ABB5SHY5055L0002 3BHE019719R0101 GVC736BE101
PSR-SPP-24UC/URM4/5X1/2X2/BHONEYWELL  FC-PSU-UNI2450U V2.1
IC9445-B200ABSCHNEIDER 140XTS00500
PM511V16
 3BSE011181R1
ABBDSMB-01C
VM600JohnsonMS-NAE5510-2
VM600ABBAO2000 LS25
VM600TRICONEX3805E
VM600ICS TRIPLEXT8110B
VM600WOG DWARD5233-2089
VM600ICS TRIPLEXT8314


查看更多 >>

产品推荐

18059884797