您好,欢迎进入厦门雄霸电子商务有限公司!

全国咨询热线

18059884797

热门关键词: ABB GE A-B TRICONEX Schneider

  • BCU-02
  • BCU-02
  • BCU-02
  • BCU-02
  • BCU-02
  • BCU-02
  • BCU-02
  • BCU-02
  • BCU-02
  • BCU-02

ABB BCU-02 控制单元

术语:描述

BCU:控制单元类型

驾驶:用于控制交流电机的变频器

FSO-xx :FSO-12或FSO-21安全功能模块

逆变器:将直流电和电压转换为交流电和电压

发光二极管:发光二极管

RDCO:DDCS通信模块

SD卡:安全数字存储卡

SDHC卡:安全的数字大容量存储卡

STO:安全扭矩关闭(IEC/EN 61800-5-2)

联系电话:18059884797

产品详情

BCU-02、BCU-12 和BCU-22是用于控制转换器的控制单元,通过光纤链路。它们包含集成的分支单元功能,用于收集和存储来自转换器模块的实时数据,以帮助故障跟踪和分析。这数据存储在插入SD-卡插槽的SDHC存储卡上,可以.由ABB服务人员分析。


控制单元需要外部24 V DC电源。它有三个选项插槽,紆I/O扩展、编码器和现场总线适配器以及可移动内存单元。为例如,如果需要更换控制单元,可以通过以下方式保留参数设置将内存单元从有故障的控制单元移至新控制单元。驱动器到驱动器链路(XD2D) 是菊花链式RS-485传输线,允许与一个主节点和多个追随者的基本主追随者通信。控件该单元还具有一个用于连接RDCO DDCS通信选件板的选件插槽。   


BCU-02 控制单元有两个光纤连接 V1 和 V2,用于连接到转换器模块。BCU-12 控制单元有一个 BPEB-05 板,而 BCU-22控制单元有两个 BPEB-05 板。每块 BPEB-05 板增加五根光纤连接。因此,BCU-12 有七个连接(V1...V7),而 BCU-22 具有十二个连接 (V1...V12)。


电缆的最大长度为:


•1 mm 塑料光缆,35 米(115 英尺)


•200m 硬包覆石英光缆,100 米(328 英尺)。


连接到一个控制单元的光纤对必须具有相同的长度。用长距离,不同长度的电缆会导致不同的延迟,这可能会产生不必要的延迟对操作的影响。

1-230524092PS31.png

BCU-02-4.png

BCU-02-5.png

BCU-02.png

BCU-02-3.png

雄霸公司简介1001.jpg

QQ图片20230509085757.jpg

BCU-02, BCU-12, and BCU-22 are control units used to control the converter through fiber optic links. They contain integrated branch unit functions for collecting and storing real-time data from converter modules to assist in fault tracking and analysis. This data is stored on the SDHC storage card inserted into the SD card slot and can be analyzed by ABB service personnel.

The control unit requires an external 24 V DC power supply. It has three option slots, including I/O expansion, encoder and fieldbus adapter, and removable memory unit. For example, if a control unit needs to be replaced, the memory unit can be moved from the faulty control unit to the new control unit by retaining the parameter settings as follows. The Drive to Drive Link (XD2D) is a daisy chain RS-485 transmission line that allows communication with basic master followers of one master node and multiple followers. The control unit also has an option slot for connecting to the RDCO DDCS communication option board.

The BCU-02 control unit has two fiber optic connections V1 and V2 for connection to the converter module. The BCU-12 control unit has one BPEB-05 board, while the BCU-22 control unit has two BPEB-05 boards. Add five fiber optic connections to each BPEB-05 board. Therefore, BCU-12 has seven connections (V1... V7), while BCU-22 has twelve connections (V1... V12).

The maximum length of the cable is:

1 mm plastic optical cable, 35 meters (115 feet)

200m hard clad quartz fiber optic cable, 100 meters (328 feet).

The fiber optic pairs connected to a control unit must have the same length. Using cables of different lengths over long distances can lead to different delays, which may have unnecessary delays and impact on operations.

查看更多 >>