基本细节:用于交流测量的TAP-210DG/3 DEIF换能器
测量:瓦特、无功、频率、相角、电压、电流精度等级0.5
安装在DIN导轨紧凑型设计上
辅助。电压:57.7…440V交流电或24…根据lEC 688
测量原理:时分乘(TDM)均方根测量
测量电压(Unom)57.7..440v ac±20%(0…测量电流(Inom)0.5..10AAC。测量范围:0..120% Inom(每相0.3VA)
测量范围0..Qnom / -Qnom. O. +Qnom
测量频率45..65赫兹(300 . . 500赫兹)
过载电压1.2 x Unom,控制/ 2 x Unom持续10秒
TAP-210DG/3交流测量用DEIF换能器
型号:TAP-210DG/3
其他信息:换能器交流测量估计运输尺寸
尺寸:263x58 × 28mm重量:4.3 kg
原产国:美国
基本细节:用于交流测量的TAP-210DG/3 DEIF换能器
测量:瓦特、无功、频率、相角、电压、电流精度等级0.5
安装在DIN导轨紧凑型设计上
辅助。电压:57.7…440V交流电或24…根据lEC 688
测量原理:时分乘(TDM)均方根测量
测量电压(Unom)57.7..440v ac±20%(0…测量电流(Inom)0.5..10AAC。测量范围:0..120% Inom(每相0.3VA)
测量范围0..Qnom / -Qnom. O. +Qnom
测量频率45..65赫兹(300 . . 500赫兹)
过载电压1.2 x Unom,控制/ 2 x Unom持续10秒
过载电流2 × lnom, cont / 10 × Inom持续10秒(最大75a)/ 40 × Inom持续1秒(最大75a)300)输出(0 . 100%)0 . . 1 ma, 0 . . 5 ma, 10 0 . .妈,0 . . 20 ma, 0 . . 1 v, v 0 . . 10
输出(20。100%)0.2 . .1, 1 . .5, 2 . .10马,4 . . 20 ma, 0.2 v . . 1, 2 . . 10 v
输出(-100% . . 0 . . + 100%)1 . . 0 . .+ 1马,5。0 . .+ 5 ma, -10。0 . .马+ 10,-20。0 . .+ 20 ma 1 . . 0 . .+ 1 v, -10。0 . .+ 10v输出负载电流输出:最大。15V,电压输出:最大。20马
根据lEC 688,精度等级0.5(-10..15..30..55°C)
响应时间/纹波< 150ms / 1%pp根据lEC 688
out / Uaux / daux / Rload Max.0.1%/10% Uaux /0.1%/45..65Hz /0.1%/ Rload-max温度系数通常为每10°C 0.15%。每10°c最大0.2%
环境温度- 10.55°C(标称)。-25 . .+ 70°℃(操作)。-40 . .+ 70°C(存储)
辅助电源(UJaux)(45.65Hz)57.7-63.5-100-110-120-127-220 -230-240-380-415- 440v AC±20%(∶3.5VA)试验电压2000V-50Hz- 1 min。
EMC符合EN 50081-1/2,EN 50082-1/2,SS4361503(PL4),IEC 255-4(3级)。CE标志,气候等级HSE,符合DIN 40040
保护外壳:IP52。终端:IP20。符合lEC 529和EN 60529端子标准。多股:2.5 mm2 /单股:4.0 mm2
*输出负载:
通过电压输出,负载不得低于规定的电阻。通过输出电流,负载不得超过规定的电阻。(输出内部保护,防止过载)。
lnstallation指令
为确保长寿,请注意以下事项:
安装的传感器(或其他设备)之间的距离不得小于10mm(建议30mm)。
当多个换能器安装在同一导轨上时,din导轨必须始终处于水平位置,而不是垂直位置。
换能器必须放置在通风良好的地方,以确保最佳的功能和使用寿命。
TAP-210DG/3 DEIF Transducers for AC measurementManufacturers : DEIF
Model(s) : TAP-210DG/3
Additional lnformation : Transducers for AC measurementEstimated Shipping Size
Dimensions: 263× 58 × 28mmWeight:4.3 kg
Country of Origin: United States of America
Essential details: TAP-210DG/3 DEIF Transducers for AC measurement
Measurement of:
watt, var,frequency, phase angle, voltage, currentAccuracy class 0.5
For mounting on DIN railCompact design
Aux. voltage: 57.7... 440V AC or 24... 220V DCAccording to lEC 688
Measuring principle Time-Division-Multiplication (TDM)RMS measurement
Measuring voltage (Unom)57.7.. 440V AC ±20%(0.. 120% Unom with separate Uaux), (口 0.5VA per phase)Measuring current (Inom)0.5..10AAC. Measuring range: 0.. 120% Inom(0.3VA per phase)
Measuring range 0.. Qnom / -Qnom..O..+Qnom
Measuring frequency 45.. 65Hz (300..500Hz)
Overloads Voltages 1.2 x Unom, cont. / 2 x Unom for 10 s
Overloads Currents 2 x lnom, cont. / 10 x Inom for 10 s (max.75A)/ 40 x Inom for 1 sec (max. 300A)Output(0..100%)0..1mA,0..5mA,0..10mA,0..20mA,0..1V,0..10V
Output (20..100%)0.2.. 1mA, 1.. 5mA, 2.. 10mA, 4..20mA,0.2..1V,2..10V
output (-100%..0..+100%)-1..0.. +1mA, -5..0.. +5mA, -10..0.. +10mA, -20..0.. +20mA, -1..0.. +1V, -10..0.. +10VOutput loads Current Output: max. 15V, voltage Output: max. 20mA
Accuracy Class 0.5 (-10..15..30..55°C) according to lEC 688
Response time/ripple <150 ms / 1%pp according to lEC 688
out / Uaux /Dfaux /口Rload Max.0.1%/10% Uaux /0.1%/45.. 65Hz /0.1%/ Rload-max. Temperature coefficient Typically 0.15% per 10°C. Max.0.2% per 10°c
Ambient temperature -10.+55°C(nominal). -25.. +70°℃ (operating). -40.. +70°C (storage)
Auxiliary supply (UJaux)(45.65Hz)57.7-63.5-100-110-120-127-220 -230-240-380-415-440V AC ±20%(口3.5VA)Test voltage 2000V-50Hz- 1 min.
EMC According to EN 50081-1/2,EN 50082-1/2,SS4361503(PL4),IEC 255-4(class 3). CE markedClimate Class HSE, according to DIN 40040
Protection Case: IP52. Terminals: IP20. According to lEC 529 and EN 60529Terminals Screw Terminals. Multi-stranded: 2.5 mm2 / single-stranded: 4.0 mm2
*Output loads:
By voltage output the load must not drop below the stated resistance. By current outputthe load must not exceed the stated resistance. (The output is internally protected againstoverload).
lnstallation instruction
To ensure a long lifetime please note the following:
The distance between the mounted transducers (or other equipment) must not be lessthan 10 mm (30 mm is recommended).
The DIN-rail must always be in horizontal position,never in vertical,when severaltransducers are mounted on the same rail.
The transducer must be situated on a well-aerated place to ensure an optimum functionand lifetime.
transducer (English name: transducer/sensor) is a detection device that can feel the information being measured, and can transform the felt information into an electrical signal or other required form of information output according to a certain law to meet the requirements of information transmission, processing, storage, display, recording and control.
The existence and development of sensors, so that the object has the sense of touch, taste and smell, so that the object becomes alive, the sensor is the extension of human features. The sensor has the characteristics of miniaturization, digitalization, intelligence, multi-function, systematization, networking, etc. It is the primary link to realize automatic detection and automatic control
B&R | 8MSA3L.E0-31 | ABB | 07DC92D GJR5252200R0101 | A-B | 2711P-B6C20D |
TRICONEX | 3504E | ICS TRIPL EX | T8850 | PROSOFT | MVI56-BAS |
AMAT | 0100-71278 | ABB | LDGRB-01 3BSE013177R1 | ABB | 3BUS208800-001 |
WOODWARD | 9907-018 2301A | ABB | LDGRB-01 3BSE013177R1 | HONEYWELL | FC-SDO-0824 V1.3 |
AMAT | 0100-77037 | EPRO | PR9376/010-01 1配件螺丝 | EL AU | C200/10/1/1/100 |
ABB | PFEA111-65 3BSE050090R65 | PROSOFT | 定制光盘 | GE | ESP10B |
KONGSBERG | RMP201-8 | ABB | PM866 3BSE050200R1 | GE | ITM11A8XJ036645 |
ABB | CMA130 3DDE300410 | FOXBORO | FCP270 P0917YZ | GE | VG5SK8I052311 PM0N2000 |
BENTLY | 60M100-00 | WOODWARD | 9907-147 | GE | HWA143-TDM-PMC-V20 |
EMERSON | MVME6100 | BENTLY | 3500/22-01-01-00 | GE | ESM10A |
EPRO | CON021 | TRICON | 4000094-310 | SCHNEIDER | PC-E984-685 |
EMERSON | VE3008 | TRICON | 4000093-310 | HIMA | H4135 |
B&W | SQ-300I 8700700-006 | ABB | IC695CPU315 | HIMA | H4135A |
Copyright © 2022-2024 厦门雄霸电子商务有限公司 版权所有 备案号:闽ICP备14012685号-33