您好,欢迎进入厦门雄霸电子商务有限公司!

全国咨询热线

18059884797

热门关键词: ABB GE A-B TRICONEX Schneider

1336-BDB-SP37C 栅极驱动板 A-B

Allen-Bradley 1336-BDB-SP37C PCB(印刷电路板)是一种停产的栅极驱动板。它是属于艾伦-布拉德利1336 (Force, Impact, Plus, Plus II和REGEN)驱动组件家族的替换部件。1336-BDB-SP37C栅极驱动板为可控硅提供栅极控制,它位于主机箱和主机驱动器的主控板之间。1336-BDB-SP37C栅极驱动板是向后兼容的,它可以作为1336-BDB-SP37-A/B板的合适替代品。该板专为1336 Plus II, Plus, Impact和Force驱动器设计,交流输入额定电压为460伏,总额定功率为150马力。该驱动器与E-Frame驱动器兼容,并支持每种外壳等级。

联系电话:18059884797

产品详情

1336-BDB-SP37C 栅极驱动板 A-B

1336-BDB-SP37C.jpg

 

概述:

 

Allen-Bradley 1336-BDB-SP37C PCB(印刷电路板)是一种停产的栅极驱动板。它是属于艾伦-布拉德利1336 (Force, Impact, Plus, Plus II和REGEN)驱动组件家族的替换部件。1336-BDB-SP37C栅极驱动板为可控硅提供栅极控制,它位于主机箱和主机驱动器的主控板之间。1336-BDB-SP37C栅极驱动板是向后兼容的,它可以作为1336-BDB-SP37-A/B板的合适替代品。该板专为1336 Plus II, Plus, Impact和Force驱动器设计,交流输入额定电压为460伏,总额定功率为150马力。该驱动器与E-Frame驱动器兼容,并支持每种外壳等级。


1336-BDB-SP37C PCB组件套件包含单个备用板和安装工具。一般建议在更换电源模块后对栅极驱动板进行测试。为了测试栅极驱动板,使用设置在电阻模式下的测试仪表测试板上的熔断器F1和F3是否打开。安装1336-BDB-SP37C PCB时,先断开电源,检查端子电压是否为零(-DC和+DC),控制电压是否无。拆下主控板,拆下旧闸门驱动板。将6个跳线连接器(J2和J6至J10)和单个风扇连接器连接到新的栅极驱动板。重新连接主控板并恢复驱动器电源。有关安装过程的更多信息,请查看在线Allen-Bradley资源手册(1336 IMPACT-6.2, 1336 FORCE-6.2或1336 PLUS-6.2)。


 

内容来自www.xbaqingplc.com转载请标注

1336-BDB-SP37C 栅极驱动板 A-B

1336-BDB-SP37C.jpg

 

 

Allen-Bradley 1336-BDB-SP37C PCB(Printed circuit board) is a discontinued gate drive board. It is a replacement part of the Allen-Bradley 1336 (Force, Impact, Plus, Plus II and REGEN) family of drive components. The 1336-BDB-SP37C gate driver board provides gate control for the thyristor, which is located between the main case and the main control board of the host driver. The 1336-BDB-SP37C gate driver board is backward compatible and can be used as a suitable replacement for the 1336-BDB-SP37-A/B board. The board is designed for the 1336 Plus II, Plus, Impact and Force drivers with AC input rated at 460 volts and a total fixed power of 150 HP. The drive is compatible with E-Frame drives and supports every case level.


The 1336-BDB-SP37C PCB Assembly kit includes a single spare board and installation tools. It is generally recommended to test the grid driver board after replacing the power module. To test the gate drive board, use the test meter set in resistance mode to test if the fuses F1 and F3 on the board are open. When installing the 1336-BDB-SP37C PCB, disconnect the power supply and check whether the terminal voltage is zero (-DC and +DC), and whether the control voltage is absent. Remove the main control board, remove the old gate drive board. Connect 6 jumper connectors (J2 and J6 to J10) and a single fan connector to the new gate driver plate. Reconnect the main control board and restore power to the driver. For more information about the installation process, check out the online Allen-Bradley Resource Manual (1336 IMPACT-6.2, 1336 FORCE-6.2 or 1336 PLUS-6.2).

1336-BDB-SP37C 栅极驱动板 A-B

姗姗名片合并2(1).jpg

1.因产品库存量大,没有搜到的型号,请联系我们。

2.所有售出的产品质量保证一年,如果您在收到货内

7天我们可以给您换货或退回任何质量问题。

3.我们是中国很好的工控产品供应商,如果您需要其他

 产品类型,请咨询我们,我们会立即给您答复。

4.如果您购买多件,我们会给您折扣,如果您已经收到价格,

请联系我们,我们将努力让您满意,我们的客户来自世界各地。


查看更多 >>

产品推荐

18059884797